Maintenance
Exchanging GapPad strips
7
37
Lenze ¯ BA_3231C ¯ 5.0
7.3 Exchanging GapPad strips
Note!
On the rear of the device, there are two GapPad strips. These strips serve
to thermally connect the device to the DIN rail. If the strips are defective,
they must be replaced ( 37).
Mounting of the device on the DIN rail is limited to 20 plug cycles. Then
the GapPad strips must be exchanged.
New GapPad strips are available from Lenze (order number EPCZMEG).
1
1
0
32xxC_006
Fig. 7−1 Rear side
Pos. Description
A Heatsink
B GapPad strip
How to exchange the GapPad strips:
4. Check the temperature of the heatsink because it may become very hot during
operation and contact may cause burns.
5. Pull off the old GapPad strip from the groove in the heatsink.
6. Remove the blue film from the self−adhesive side of the new GapPad strip and
stick the GapPad strip into the groove.
7. Repeat these steps for the second GapPad strip.