6 Commissioning
6.5 Going online with »Engineer« via TCI
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. In »STEP7« in the »HW Konfig« ...
create the Lenze PROFIBUS stations with the corresponding station addresses and
•create a PROFIBUS network.
Here a Servo Drive 9400 (address 3) and an Inverter Drive 8400 (address 4) are operated on
the PROFIBUS.
The names of the PROFIBUS slaves in the »HW Konfig« must be identical to those of the
corresponding Lenze axes in the »Engineer« (here "9400" and "8400").
The selection of the process data configuration has no impact on TCI communication.