Drive PLC Developer Studio
L
35DDS DE/EN 2.1
4.4.3 Log in the automation system
The car park program canbe transferredto theautomation systemand startedafter the communication
parameters have been determined.
Tip!
If the PC is not connected to an automation system, the car park program can also be executed in the
Simulation Mode in DDS (only with the DDS Professional version):
Select Onlin e
Log in, to log in the automation system and change to the online mode.
(Also with activated simulation mode.)
After log in
all online functions in the menu Online are available.
the Declaration editor and the function plan editor of the organization unit Counter are
combined in a monitor window, i. e. the actual variable values are displayed and the Boolean
variables are highlighted (
TRUE =blue,FALSE =black).
Warning!
For use of an automation system with motor control
(e. g. 9300 Servo PLC):
Do not use the commands Controller enable/Controller inhibit for an emergency stop via PC, since
these commands are transferred to the controller with a delay.