EDS84AYCIB EN 4.0 - 11/2010 L 67
E84AYCIB communication manual (INTERBUS)
Parameter reference
Parameters of the communication module
C13892
C13893
Parameter | Name:
C13892 | PCP - length
Data type: UNSIGNED_8
Index: 10683
d
= 29BB
h
Setting of the number of the parameter data words to be used (PCP)
The setting is activated ...
if all DIP switches (S205) are in the "OFF" position;
after executing the "11: Save start parameters" device command via standard device code C00002 and
performing another mains switching of the communication module/drive afterwards.
Setting the number of parameter data words (PCP)
( 36)
Selection list (Lenze setting printed in bold)
0No PCB data
11 word
22 words
44 words
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13893 | Process data length
Data type: UNSIGNED_8
Index: 10682
d
= 29BA
h
Setting of the number of the process data words to be used (PD)
The setting is activated ...
if all DIP switches (S205) are in the "OFF" position;
after executing the "11: Save start parameters" device command via standard device code C00002 and
performing another mains switching of the communication module/drive afterwards.
Setting the number of process data words (PD)
( 35)
Selection list (Lenze setting printed in bold)
0No process data
11 word
22 words
33 words
44 words
55 words
66 words
77 words
88 words
99 words
10 10 words
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT