Lenze E94AYCIB Manual do Utilizador Página 44

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 78
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 43
9 Parameter data transfer
9.3 Supported PMS services
44
Lenze · E94AYCIB communication module (INTERBUS) · Communication Manual · DMS 4.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.3.7 Status
The "Status" PMS service provides status information about the inverter.
The inverter provides the following values:
Status Value Description
Logical status 0 = ready for communication Information about the current operating
mode of the inverter with regard to
communication
Physical status • 0 = ready for operation (device state
"OPERATION ENABLED")
1 = ready for operation to a limited extent
(all other device states)
Information about the current operating
status of the
inverter.
Local Detail 0 Is not supported.
Vista de página 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 77 78

Comentários a estes Manuais

Sem comentários