Lenze ECSEAxxx Manual do Utilizador Página 84

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 200
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 83
Safety instructions
Residual hazards
2
84
EDKCSEX064 DE/EN/FR 6.0
Motor protection
ƒ Only use motors with a minimum insulation resistance of û = 1.5 kV,
min. du/dt = 5 kV/ms.
Lenze motors meet these requirements.
ƒ When using motors with an unknown insulation resistance, please
contact your motor supplier.
ƒ Some settings of the axis module lead to an overheating of the connected
motor, e.g. longer operation of self−ventilated motors with low speeds.
ƒ Use PTC thermistors or thermostats with PTC characteristic for motor
temperature monitoring.
Vista de página 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 199 200

Comentários a estes Manuais

Sem comentários