Vista de página 40
Drive PLC
System blocks
2.10 FCODE_FreeCode (node number 141)
2−27
L
DrivePLC DE 6.0
2.10.1 Inputs_FCODE
System variables
Variable Data type Signal type Address Display
code
Display
format
Notes
FCODE_bC135Bit0_b
...
FCODE_bC135Bit15_b
Bool binary
default = 0
Also output variables
(see table below)
FCODE_bC471Bit0_b
...
FCODE_bC471Bit15_b
%IX141.0.0
...
%IX141.0.15
default = 0
FCODE_bC471Bit16_b
...
FCODE_bC471Bit31_b
%IX141.1.0
...
%IX141.1.15
FCODE_nC472_1_a
...
FCODE_nC472_20_a
Integer analog
%IW141.2
...
%IW141.21
default = 0.00 %
FCODE_nC473_1_a
...
FCODE_nC473_10_a
%IW141.22
...
%IW141.31
default = 0
C0473/1,2 = 1
FCODE_dnC474_1_p
...
FCODE_dnC474_5_p
Double integer position
%ID141.16
...
%ID141.20
default = 0
FCODE_nC475_1_v
Integer Velocity
%IW141.42
default = 0
FCODE_nC475_2_v %IW141.43
Example
It is possible to enter a percentage [%] under PLC code C0472/1 by using, for instance, the keypad.
This value is directly assigned to the variable FCODE_nC472_1_a (data type "Integer") and can be
processed further in the PLC program.
2.10.2 Outputs_FCODE
System variables
Variable Data type Signal type Address Display
code
Display
format
Notes
FCODE_wC135 WORD %QW141.0
FCODE_bC135Bit0_b
...
FCODE_bC135Bit15_b
Bool binary
%QX141.0.0
...
%QX141.0.15
Also input variable
(see table above)
FCODE_wC150 WORD %QW141.1
FCODE_bC150Bit0_b
...
FCODE_bC150Bit15_b
Bool binary
%QX141.1.0
...
%QX141.1.15