Lenze MCH Series Drives Modbus Communications Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Lenze MCH Series Drives Modbus Communications. Lenze MCH Series Drives Modbus Communications User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - MCH Series Drives

MCH Series Drives Modbus Communications Reference Guide

Página 2 - About These Instructions

RG-MHMOD 6Drive Setup & Operation4 MCH Drive Setup & Operation4.1 Serial AddressAll AC Tech drives have a Serial Address Parameter that must

Página 3 - Contents

7 RG-MHMODDrive Setup & Operation• Setting the control parameter to “NORMAL” or “NORM NO HAND” gives the user read/write access to the Program

Página 4

RG-MHMOD 8Drive Setup & Operation4.5 Unlocking & Locking Programming Parameters onlyRegisters #49 and #1 are used in Unlocking and Locking Pr

Página 5 - Safety Information

9 RG-MHMODDrive Setup & Operation − A Watchdog failure can be recognized by reading the drive status (AC Tech Registers #24 – 29) and looking at

Página 6

RG-MHMOD 10Drive Control & Communication4.9 Start/Stop, Speed Control and Parameter Change OperationThe typical sequence for a Start/Stop, Speed

Página 7 - Introduction

11 RG-MHMODDrive Control & Communication5 MCH Drive Control RegistersTable 6 describes the MCH Drive Control Registers in ascending order of AC

Página 8

RG-MHMOD 12Drive Control & CommunicationACT# (HEX representation)REGISTER NAMER/W/RSMESSAGE MIN MAX UNITS[NOTE]orSection40 (28) Keypad Speed Comma

Página 9 - Data & Register Format

13 RG-MHMODDrive Control & Communication5.2 Drive Control - Register #1Table 8 illustrates the Data format of Register #1, Drive Control.Table 8

Página 10 - Drive Setup & Operation

RG-MHMOD 14Drive Control & Communication5.3 Drive Size - Register #21Table 9 lists the MCH Series drives. Register 21 will contain the value in t

Página 11

15 RG-MHMODDrive Control & CommunicationNOTE 3a - Command Speed (Register #24 Bytes D1H and D1L or Register #25)• In hundredths of a Hz• Most s

Página 12

This documentation applies to the use of an MCH Series Variable Frequency Drive in a Modbus Network and should be used in conjunction with the MCH Ser

Página 13

RG-MHMOD 16Drive Control & Communication5.4.3 Control Mode - Registers #24 & 27Table 13 lists the Control Mode (Register #24 byte D4L or Regi

Página 14

17 RG-MHMODDrive Control & Communication5.4.6 Present Fault - Registers #24 & 29Table 16 lists the Present Fault (Register #24 byte D6H or R

Página 15 - 11 RG-MHMOD

RG-MHMOD 18Drive Control & Communication5.6 Kilowatt Hours - Registers #32 & 33Kilowatt hours are listed as a 32-bit value.Register #32 - Kil

Página 16 - 5.1 Abbreviations

19 RG-MHMODDrive Control & Communication5.11 Unlock Commands - Register #48Register #48 (Unlock Commands) unlocks commands by using 0000 for the

Página 17

RG-MHMOD 20Drive Control & Communication6 MCH Programming Parameters6.1 FormatNOTE - AttentionParameter list presented in Section 6.2 is valid on

Página 18

21 RG-MHMODDrive Control & Communication6.2 Parameter ListAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of Adj

Página 19

RG-MHMOD 22Drive Control & CommunicationAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of AdjustmentModbus value

Página 20

23 RG-MHMODDrive Control & CommunicationAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of AdjustmentModbus value

Página 21

RG-MHMOD 24Drive Control & CommunicationAC TechRegisterNumber(hexadecimalrepresentation)Parameter 1Parameter Name Range of AdjustmentModbus value

Página 22

25 RG-MHMODDrive Control & CommunicationNOTE 4 - Acceleration LimitsAcceleration LimitsHP Adjustment Range0.25 - 20 1 - 36000 (0.1 - 3600 sec)25

Página 23 - 5.13 Register Version

i RG-MHMODContents1 Safety Information ...

Página 24 - 6 MCH Programming Parameters

RG-MHMOD 26Drive Control & Communication7 Quick Start InstructionsFollow these Quick Start instructions to use ModBus Communications for basic ne

Página 25 - 6.2 Parameter List

27 RG-MHMODDrive Control & CommunicationUnlocking the Drive:1. The first write necessary to the drive to perform any function (start,change speed

Página 26 - RG-MHMOD 22

RG-MHMOD 28Drive Control & Communication7.4 Basic Drive StatusAC Tech register 24 is a 6 word entity containing the drive’s status information. T

Página 27 - 23 RG-MHMOD

Lenze AC Tech Corporation630 Douglas Street • Uxbridge MA 01569 • USASales: 800-217-9100 •Service: 508-278-9100www.lenze-actech.comRG-MHMOD-e7

Página 28 - RG-MHMOD 24

RG-MHMOD iiContents5 MCH Drive Control Registers ...115.1 A

Página 29

1 RG-MHMODSafety Information1 Safety Information1.1 Warnings, Cautions and Notes1.1.1 GeneralSome parts of Lenze controllers (frequency inverters,

Página 30 - 7 Quick Start Instructions

RG-MHMOD 2Safety Information1.1.4 Electrical ConnectionWhen working on live drive controllers, applicable national regulations for the prevention of

Página 31 - 7.3 Basic Drive Commands

3 RG-MHMODIntroduction2 IntroductionThis document defines the specifics required for Modbus serial communication with a Lenze-AC Tech standard MCH Ser

Página 32 - 7.4 Basic Drive Status

RG-MHMOD 4Introduction16 Preset Multiple Registers (4X references). Although the function is for multiple registers, we will accept only a single reg

Página 33 - Lenze AC Tech Corporation

5 RG-MHMODData & Register Format3 Data Representation - Internal and External3.1 Register FormatAll registers are 16 bits. The data within the

Comentários a estes Manuais