Lenze MDFQA Operating Instructions Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Equipamento Lenze MDFQA Operating Instructions. Lenze MDFQA Operating Instructions User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - 0.5 Nm ... 1100 Nm

.NójÄ.NójäOperating Instructions ENM...MCA, MCS, MQA, MDKS, MDFQA0.5 Nm ... 1100 NmAsynchronous servo motors / synchronous servomotors

Página 2 - 0Abb. 0Tab. 0

Safety instructionsForeseeable misuse2EN 10Lenze ¯ BA 33.0006 ¯ 3.02.3 Foreseeable misuse¯ Do not operate the motors– ... in explosion−protected

Página 3 - Contents i

Safety instructionsResidual hazards2EN 11Lenze ¯ BA 33.0006 ¯ 3.0Motor protection¯ Installed thermal detectors are no full protection for the mac

Página 4 - Contentsi

Product descriptionIdentification3EN 12Lenze ¯ BA 33.0006 ¯ 3.03 Product description3.1 IdentificationTypes MC., MQASynchronous servo motors Asyn

Página 5 - About this documentation 1

Product descriptionIdentificationNameplate3EN 13Lenze ¯ BA 33.0006 ¯ 3.0 3.1.1 NameplateAsynchronous and synchronous servo motorsNameplate SYN−00

Página 6 - About this documentation

Product descriptionIdentificationNameplate3EN 14Lenze ¯ BA 33.0006 ¯ 3.0No. Explanation1 Manufacturer2 Motor type3 Lenze motor type4 Rated voltag

Página 7

Product descriptionIdentificationProduct key3EN 15Lenze ¯ BA 33.0006 ¯ 3.0 3.1.2 Product keyServo motors MCA, MCS, MQA MLegend for product key0

Página 8

Product descriptionIdentificationProduct key3EN 16Lenze ¯ BA 33.0006 ¯ 3.05 Design, shaft, concentricity/vibrational severity/direct gearbox atta

Página 9

Product descriptionIdentificationProduct key3EN 17Lenze ¯ BA 33.0006 ¯ 3.0 Servo motors MDLLL MLegend for product key0 TypeD Three−phase AC cur

Página 10 - Safety instructions

Product descriptionIdentificationProduct key3EN 18Lenze ¯ BA 33.0006 ¯ 3.0 Feedback system Resolver/encoderLegend for the product keyTypeRSRVIG

Página 11

Technical dataGeneral data and operating conditions4EN 19Lenze ¯ BA 33.0006 ¯ 3.04 Technical data4.1 General data and operating conditions Gene

Página 12 - Product description

 Please read these instructions before you start working!Follow the enclosed safety instructions.0Abb. 0Tab. 0

Página 13

Technical dataGeneral data and operating conditionsSetting the switching frequency to the rated motor data4EN 20Lenze ¯ BA 33.0006 ¯ 3.04.1.1 Set

Página 14

Mechanical installationImportant notes5EN 21Lenze ¯ BA 33.0006 ¯ 3.05 Mechanical installation5.1 Important notes Danger!Some of the motors mount

Página 15

Mechanical installationHolding brake (option)Installation5EN 22Lenze ¯ BA 33.0006 ¯ 3.05.3.1 InstallationImportant notes¯ The mounting surface mu

Página 16

Mechanical installationHolding brake (option)Installation5EN 23Lenze ¯ BA 33.0006 ¯ 3.0The brakes operate according to the closed−circuit princip

Página 17

Mechanical installationHolding brake (option)Permanent magnet holding brakes5EN 24Lenze ¯ BA 33.0006 ¯ 3.05.4.1 Permanent magnet holding brakes T

Página 18 - Resolver/encoder

Mechanical installationHolding brake (option)Permanent magnet holding brakes5EN 25Lenze ¯ BA 33.0006 ¯ 3.0Wear of permanent magnet brakes If ap

Página 19 - Technical data

Mechanical installationHolding brake (option)Spring−applied holding brakes5EN 26Lenze ¯ BA 33.0006 ¯ 3.05.4.2 Spring−applied holding brakes These

Página 20

Mechanical installationHolding brake (option)Spring−applied holding brakes5EN 27Lenze ¯ BA 33.0006 ¯ 3.0Component Effects Influencing factors Cau

Página 21 -  Danger!

Electrical installationImportant notes6EN 28Lenze ¯ BA 33.0006 ¯ 3.06 Electrical installation6.1 Important notes Danger!Hazardous voltage on the

Página 22 - Mechanical installation

Electrical installationWiring according to EMC6EN 29Lenze ¯ BA 33.0006 ¯ 3.06.2 Wiring according to EMCThe EMC−compliant wiring of the motors is

Página 23

Contents iEN 3Lenze ¯ BA 33.0006 ¯ 3.01 About this documentation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 24

Electrical installationPlug connectorsHolding brake6EN 30Lenze ¯ BA 33.0006 ¯ 3.0MCA 19...21, MCS 14...19, MQA 20 (external view of poles)Pin Sta

Página 25

Electrical installationPlug connectorsFeedback system6EN 31Lenze ¯ BA 33.0006 ¯ 3.06.3.4 Feedback systemResolver (external view of poles)Pin Desi

Página 26

Electrical installationTerminal boxFeedback system6EN 32Lenze ¯ BA 33.0006 ¯ 3.0 6.4 Terminal boxTerminal box with knock out Terminal box with s

Página 27

Electrical installationTerminal boxCable glands for the fan terminal box6EN 33Lenze ¯ BA 33.0006 ¯ 3.0Cable glands for the fan terminal boxMotor

Página 28 -  Danger!

Electrical installationTerminal boxFan6EN 34Lenze ¯ BA 33.0006 ¯ 3.06.4.4 Fan1−phaseTerminal Standard description MeaningPE PE conductorU1U2U1U2

Página 29 - Electrical installation

Electrical installationTerminal boxFeedback system6EN 35Lenze ¯ BA 33.0006 ¯ 3.06.4.5 Feedback systemResolverTerminal Designation MeaningB1B2+Ref

Página 30

Safety engineering7 Lenze 36BA 33.0006 3.07 Safety engineeringMotor−encoder combinationsDrive systems with Servo Drives 9400 and safety module

Página 31

Commissioning and operationImportant notes8EN 37Lenze ¯ BA 33.0006 ¯ 3.08 Commissioning and operation8.1 Important notesFor trial run without ou

Página 32

Commissioning and operationFunctional test8EN 38Lenze ¯ BA 33.0006 ¯ 3.08.3 Functional test¯ Check all functions of the drive after commissioning

Página 33

Maintenance/repairImportant notes9EN 39Lenze ¯ BA 33.0006 ¯ 3.09 Maintenance/repair9.1 Important notes Danger!Hazardous voltage on the power con

Página 34

ContentsiEN 4Lenze ¯ BA 33.0006 ¯ 3.07 Safety engineering 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 35

Maintenance/repairMaintenance operationsHolding brake9EN 40Lenze ¯ BA 33.0006 ¯ 3.09.2.3 Holding brakeThe brakes need to be checked on a regular

Página 36 - Safety engineering7

Maintenance/repairMaintenance operationsFan with dust protection filter9EN 41Lenze ¯ BA 33.0006 ¯ 3.09.3.2 Fan with dust protection filter Dry−ty

Página 37 - Commissioning and operation

Maintenance/repairMaintenance operationsMotor plug connection assignment9EN 42Lenze ¯ BA 33.0006 ¯ 3.09.3.4 Motor plug connection assignment This

Página 38

Maintenance/repairMaintenance operationsPlug−in connector at the cable end9EN 43Lenze ¯ BA 33.0006 ¯ 3.0Synchronous servo motorsMotor type Plug s

Página 39

Maintenance/repairRepair9EN 44Lenze ¯ BA 33.0006 ¯ 3.0BlowerBlower Plug size *Screw plug SpeedTecSpare partdesignationCoding in the systemcable t

Página 40

Troubleshooting and fault elimination 10EN 45Lenze ¯ BA 33.0006 ¯ 3.010 Troubleshooting and fault elimination If faults occur during operation o

Página 41 - Maintenance/repair

Troubleshooting and fault elimination10EN 46Lenze ¯ BA 33.0006 ¯ 3.0Fault Cause RemedyMotor too hotCan only be evaluated bymeasuring the surfacet

Página 42

Notes !EN 47Lenze ¯ BA 33.0006 ¯ 3.0

Página 43

© 01/2014 | BA 33.0006 | .Nój | 3.0 | TD09 Lenze Drives GmbHPostfach 10 13 52D−31763 HamelnGermany+49(0)5154/ 82−0+49(0)5154/ 82−28 00Lenze

Página 44

About this documentation 1EN 5Lenze ¯ BA 33.0006 ¯ 3.01 About this documentationContents¯ The present operating instructions are intended for saf

Página 45

About this documentationDocument history1EN 6Lenze ¯ BA 33.0006 ¯ 3.01.1 Document historyMaterial number Version Description13302706 1.0 07/2009

Página 46 - Lenze ¯ BA 33.0006 ¯ 3.0

About this documentationNotes used1EN 7Lenze ¯ BA 33.0006 ¯ 3.0 1.4 Notes usedThe following pictographs and signal words are used in this documen

Página 47

Safety instructionsGeneral safety instructions for drive components2EN 8Lenze ¯ BA 33.0006 ¯ 3.02 Safety instructions2.1 General safety instructi

Página 48 - 10987654321

Safety instructionsApplication as directed2EN 9Lenze ¯ BA 33.0006 ¯ 3.0¯ Only qualified skilled personnel are permitted to work with or on Lenze

Comentários a estes Manuais