Lenze E84DGFCA Manual do Utilizador Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 74
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 7
1 About this documentation
1.3 Terminology used
8
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1.3 Terminology used
Term Meaning
AS-Interface The AS-Interface (actuator/sensor interface) ...
• is an international standard for fieldbus communication.
• is used in decentralised applications as fieldbus communication on the
lowest control level.
AS-i
Inverter Lenze frequency inverter of the "Inverter Drives 8400 motec" product series
Standard device
Drive Unit
Communication unit
Wiring Unit
The Inverter Drive 8400 motec has a modular structure. It consists of the
following modules: "Drive Unit", "Communication Unit" and "Wiring Unit".
• The drive unit is available in different power settings.
• The Communication Unit is available in the following versions:
•No fieldbus
AS-i option
CANopen option
•PROFIBUS option
•PROFINET option
•EtherCAT option
EtherNet/IP option
• The wiring unit provides flexible connection possibilities for a simple
integration into the power supply of the machine.
»Engineer« Lenze PC software which supports you in "engineering" (parameter setting,
diagnosing, and configuring) during the entire life cycle, i.e. from planning to
maintenance of the commissioned machine.
Code Parameter which serves to parameterise or monitor the inverter. In general
linguistic usage, this term is also referred to as "index".
Subcode If a code contains several parameters, these are stored in "subcodes".
In this documentation, a slash "/" is used as a separator between code and
subcode (e.g. "C00118/3").
The term is usually called "subindex".
Lenze setting This setting is the default factory setting of the device.
Basic setting
HW Hardware
SW Software
CTT2 transmission
(Combined Transaction Type 2)
Serial data transmission is established between master and slave (clock in/out,
data in/out). This channel serves for ...
• acyclic transmission of data records;
• acyclic transmission of the extended process image.
Data set transmission In the case of CTT2 transmission, data records are transmitted between the
master and the slave only on request. During acyclic data record transmission,
the cyclic transmission of the extended process image is interrupted.
Process image In the case of the Inverter Drive 8400 motec, 4 bits of control data (PAA) are
transmitted to the slave every time the slave is called. The slave returns a
response containing 6 bits of information (PAE). The transmission is carried out
at least every 10 ms (AS-i cycle
( 31), depending on the addressing
assignment).
In the case of extended process images, continuous transmission of 4 bytes per
direction between the master and the slave takes place.
Parameter echo (diagnostics via
parameter data channel)
The "Write Parameter" AS-i command serves to transmit 4 parameter bits to the
slave.
In the response message, the slave returns 4 bits (16 bit combinations) of status
information.
ICs Circuits which efficiently perform the described tasks of a slave.
MCU Microcontroller
ASIC Application specific integrated circuit
Vista de página 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 73 74

Comentários a estes Manuais

Sem comentários