Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17 110
13 Parameter reference
13.3 Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14851
C14852
C14853
Parameter | Name:
C14851 | All words from scanner
Data type: INTEGER_16
Index: 9724 = 0x25FC
Display of the I/O data words transferred from the scanner to the communication module (adapter).
In the subcodes, all I/O data words transferred from the scanner are displayed. However, only the configured I/O
data words are valid.
Display range (min. value | unit | max. value)
-32768 32767
Subcodes Info
C14851/1
...
C14851/32
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14852 | All words to standard device
Data type: INTEGER_16
Index: 9723 = 0x25FB
Display of the I/O data words transferred from the communication module to the standard device.
Display range (min. value | unit | max. value)
-32768 32767
Subcodes Info
C14852/1
...
C14852/32
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14853 | All words from standard device
Data type: INTEGER_16
Index: 9722 = 0x25FA
Display of the I/O data words transferred from the standard device to the communication module.
Display range (min. value | unit | max. value)
-32768 32767
Subcodes Info
C14853/1
...
C14853/32
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT