5.6 Creating a STEP7 program
The Lenze function blocks can be integra ted in different ways. For a simple test, the blocks supplie d
in the SIMATIC Manager can be copied from the library to a new project.
Note!
If you have configured drive controllers in your project which are temporarily disconnected from the
mains, please observe the following:
Drive controllers which are completely disconnected from the mains and are fully de-energised,
are no longer recognised as PROFIBUS devices by the PLC. This c an be prevented by supplyi ng
the function block/fieldbus module with an external voltage.
Instances of the FB DRIVE for disconnected drive controll ers have to be skipped in the PLC
program.
A query can be performed via the status words of the blocks FC91, FC92, FC93 or FC94.If
the status word of these blocks indicates ”0”, the drive c ontroller is not switched on (or not
available) and the co rresponding FB DRIVE instance must be skipped.
(^ 113)
If an S7-300 is used, you can address drive controllers which are directly connected to the PROFIBUS
master of the CPU card and drive controllers which are connected with an external PROFIBUS
communication processor (CP).
For this, please use the block FB DRIVE CP instead of the block FB DRIVE.
In the first step, communication is to be performed via OPC with only one drive connected to the
PROFIBUS master of the CPU.
5.6.1 Accessing a drive via OPC
Tip!
You can use the provided example programs for initial commissioning. In this case, you only ha ve to
adapt the hardware confi guration to your system envi ronment.
(^ 87)
If you want to create a program on your own, you simply have to integrate the supplied blocks into the
SIMATIC Manager.
Proceed as follows to create your own program:
1. Crea te a new project with the block OB1.
2. Select File
WOpen, click Libraries and select the LenzeDriveServer.
In the new window, you will find all blocks c ontained in the “LenzeDriveServer” library.
3. SimplydraganddropblocksFB90, DB80 and DB81 into your new project .
4. Call an instance of FB90 in OB1.
When programming in IL enter the following program code:
CALL FB90, DBxxx
(xxx represents a free data block number)
This call automatically creates the data block.
5. Edit the list of transfer parameters.