EDK94AYCEC DE/EN/FR/ES/IT 1.012
DUMMY_NUM_Reset−KommModul Demontage
0Fig. 0Tab. 0
Scope of supply
Pos. Description
E94AYCEC communication module , ETHERNET Powerlink (CN)
Mounting Instructions
Connections
Pos. Description
X250 Connection to the external supply of the communication module
Design: plug connector with screw connection, 2−pole
X251
Connection for ETHERNET Powerlink
Design: RJ45 socket in accordance with IEC 60603−7, with integrated LEDs
X252
DIP switch
E94YCEP001D
Pos. Description
S233 Node addressing:
The node address results from the sum of all switches being set to "ON".
l Example: Switches 32, 8, 4 = ON address = 44
l Address area:
1 100 with E94AYCEP as master
1 239 with another master
Note!
The Lenze setting of all switches is OFF.
Observe the information on how to set the node address in the ETHERNET
Powerlink Communication Manual.