Lenze E94AZMS0314 Manual do Utilizador Página 46

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 132
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 45
5
Mechanical installation
Side−by−side mounting − device size I
EDK94AZMS DE/EN/FR/ES/IT 8.0
46
l
H1_MechINS−Fi NbMontage_GG2−3_EN
Screws Tightening torque
E94AZxS0044
2 x M5x20
3.4 Nm (30 lb−in)
E94AZxS0104
E94AZxS0294 2 x M5x25
3. Under limited space conditions, filter and mounting base can be connected
electrically. (^ 49)
4. Screw the filter onto the mounting plate.
Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
If further devices are to be mounted directly adjacent on the right−hand side of the
filter, do not tighten the screws fully before all devices are mounted and aligned.
Tightening torque: 3.4 Nm (30 lb−in).
I Tip!
Under limited space conditions, filter and mounting base can be connected
electrically when step 2 has been carried out.
Side−by−side mounting − device size I
Mounting steps
How to proceed for side−by−side mounting:
1. Prepare M5 threaded holes on the mounting plate, for instance according to the
mounting grid.
Always use all mounting points specified.
2. Mount the filter on the prepared mounting plate to the left of the mounting base.
Use M5 screw and washer assemblies or M5 hexagon socket screws with washers.
If further devices are to be mounted directly adjacent on the right−hand side of the
filter, do not tighten the screws fully before all devices are mounted and aligned.
Tightening torque: 3.4 Nm (30 lb−in).
Vista de página 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 131 132

Comentários a estes Manuais

Sem comentários