6 Technical data
Protective insulation
EDKMF2113 DE/EN/FR 5.1
72
H1_Daten−AlleMaßeInMM
Insulation between outgoing bus and ... Type of insulation (to EN 61800−5−1)
l Reference earth / PE
Functional insulation
l With external supply
No electrical isolation
l Power stage
– 820X / 821X Basic insulation
– 822X / 8200 vector Reinforced insulation
– 93XX / 9300 Servo PLC Reinforced insulation
– ECS servo system Reinforced insulation
l Control terminals
– 820X / 8200 vector (with internal supply) No electrical isolation
– 8200 vector (with external supply) Basic insulation
– 821X Functional insulation
– 822x Basic insulation
– Drive PLC Basic insulation
– 93XX / 9300 Servo PLC Basic insulation
– ECS servo system Reinforced insulation
l Incoming bus (IN)
Electrical isolation