EDS94TA10060xxxx EN 1.2 - 03/2010 L 23
9400 Technology applications | Positioning sequence control
Short setup
Step 3: Parameterising the program flow
4.6.6 Program step 6: Positioning action 2
Tip!
In a later step, sequence control input 6 will be connected with digital input DO6.
Click Profile settings to open the following dialog box:
1. Select Profile no. 2.
2. Select "Absolute" as positioning mode.
3. Select the profile parameters as described above.
4. Click Back to close the dialog box again.
Action Comment Parameter Setting
When sequence control input 6 is set to "1", go back
to start position.
Selection Action Number: 2
Start with: Input 6
Profile no.: 2
Jump destination: 0