9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Assignment of the I/O terminals
24 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.2.2 Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for
the "Synchronism" technology application.
r The default signal configuration if required can be easily changed by parameterising
the multiplexer parameters assigned.
Analog outputs
Digital outputs
State bus
Display elements
Terminal X3 Signal (Lenze setting) Signal configuration
AO1 Motor speed
Scaling: ±10 V motor reference speed (C00011)
C03110/1
AO2 Motor torque (setpoint)
Scaling: ±10 V Motor reference torque (C00057/2)
C03110/2
Terminal X4 Signal (Lenze setting) Signal configuration
DO1 Status "Drive ready"
DC-bus voltage is available and no error has occurred.
C03100/1
DO2 Status "Electrical shaft enabled" C03100/2
DO3 Status "Limitation active"
A setpoint is limited at the moment.
C03100/3
DO4 "Error" status
If the controller is in the error state, the digital output DO4 is set
to HIGH level.
C03100/4
Terminal X2 Signal (Lenze setting) Signal configuration
SB "Application error" status
The state bus is put in the "error" status.
C03100/5
User LED Signal (Lenze setting) Signal configuration
Status "Electrical shaft enabled" C03100/6
GA
AO1
AO2
GO
24O
DO1
DO2
DO3
DO4
GE
24E
SB