L-force | PLC Designer - SoftMotion
The SM_CNC.lib library
SMC_Interpolator2Dir
193 L DMS 5.2 EN 03/2011 TD17
Inputs (VAR_IN)
dAngleTol: LREAL
Angle tolerance for the reverse path. Typically identical to the angle tolerance of the
original path.
nSizeOutQueue: UDINT, pbyBufferOutQueue: POINTER TO BYTE
Size of and pointer to data buffer in which the reverse path is to be stored. This buffer must
be large enough to hold the complete path.
Ipo2d: SMC_Interpolator2Dir
SMC_Interpolator2Dir instance for which the reverse path is to be generated