L-force | PLC Designer - SoftMotion
The SM_Trafo.lib library
Transformation function blocks
218 L DMS 5.2 EN 03/2011 TD17
9.1.1.2 SMC_TRAFOF_Gantry2
Inputs/outputs (VAR_IN_OUT)
DriveX, DriveY: AXIS_REF
x, y axis
Inputs (VAR_IN)
dOffsetX, dOffsetY: LREAL
Offset for x and y axis. Same values as described for SMC_TRAFO_Gantry2
minX, maxX, minY, maxY: LREAL
Motion range (for visualisation)
Outputs (VAR_OUT)
dx, dy: LREAL
x, y position in geo coordinates
dnx, dny, dnOffsetX, dnOffsetY: LREAL
Standardised x and y position [0...1] and offsets (for visualisation).
ratio: LREAL
Ratio of x interval and y interval (for visualisation)