Lenze EVS9332xK Manual do Utilizador Página 199

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 386
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 198
Function library
Function blocks
3.2.52 Free codes (FCODE) of the measuring systems
3−171
l
EDSVS9332K−EXT EN 4.0
3.2.52 Free codes (FCODE) of the measuring systems
A measuring system is described via the gearbox factor (numerator and denominator) and the feed
constant. These scaling factors have an effect on the conversion of units into increments.
The measuring systems have an effect on free codes.
Measuring system of the master phase (X axis)
l FCODE1476/1 ... FCODE1476/16
l Gearbox factor of the numerator: C1303/1
l Gearbox factor of the denomiator: C1303/2
l Feed constant: C1304
l The selection is effected in [m_units]
Measuring system of the actual value (Y axis)
l FCODE1477/1 ... FCODE1477/16
l Gearbox factor numerator: C1305/1
l Gearbox factor denomiator: C1305/2
l Feed constant: C1306
l The selection is effected in [s_units]
Measuring system Z (Z axis)
l FCODE1478/1 ... FCODE1478/6
l Gearbox factor numerator: C1680/1
l Gearbox factor denomiator: C1680/2
l Feed constant: C1681
l The selection is effected in [z_units]
) Note!
The Z measuring system has no effect on the profiles and displays.
The profiles are calculated in PC programs. If you want to calculate profiles via the
Z measuring system, you have to adapt the corresponding PC programs.