Function library
Function blocks
3.2.76 Angle integrator (PHINT1, PHINT2, PHINT3)
3−246
l
EDSVS9332K−EXT EN 4.0
3.2.76.3 Input value with sign reversal (PHINT3)
C1150 = 2
The input PHINT3−LOAD is state−triggered (HIGH level).
l PHINT3−LOAD = HIGH
The integrator is loaded with the input value at PHINT3−SET.
Sets the output PHINT3−STATUS = LOW.
PHINT3-OUT
Change of sign at the input
PHINT3-STATUS
+C1151
-C1151
t
t
9300kur090
Fig. 3−201 Function of PHINT3 with sign reversal of the input value when C1150 = 2
l The FB integrates speed or velocity values at PHINT3−IN to a angle (distance).
l PHINT3−OUT outputs the counter content of the bipolar integrator.
A positive value at PHINT3−IN increments the integrator (counter content is increased).
A negative value at PHINT3−IN decrements the integrator (counter content is reduced).
l If the counter content exceeds the value of (+) C1151,
the value of C1151 is subtracted from the counter content
PHINT3−STATUS switches to HIGH for 1 ms.
l If the counter content falls below the value of (−) C1151,
the value of C1151 is added to the counter content
PHINT3−STATUS switches to HIGH for 1 ms.