2.2.7 Changeover (L_ASW)
Function library LenzeDrive.lib
Analog signal processing
2−12
L
LenzeDrive.lib EN 1.7
2.2.7 Changeover (L_ASW)
This FB switches between two integer values. So it is, for example, possible to change between an
initial diameter and a calculated diameter during winding.
n I n 1 _ a
n O u t _ a
L _ A S W
0
1
n I n 2 _ a
b S e t _ b
Fig. 2−10 Changeover (L_ASW)
VariableName DataType SignalType VariableType Note
nIn1_a Integer analog VAR_INPUT
nIn2_a Integer analog VAR_INPUT
bSet_b Bool binary VAR_INPUT
nOut_a Integer analog VAR_OUTPUT
Function
Control signal Output signal
bSet_b = TRUE nOut_a = nIn2_a
bSet_b = FALSE nOut_a = nIn1_a