2.5.2 Conversion of phase−angle to analog (L_CONVPA)
Function library LenzeDrive.lib
Signal conversion
2−50
L
LenzeDrive.lib EN 1.7
2.5.2 Conversion of phase−angle to analog (L_CONVPA)
This FB converts a phase−angle signal into an integer signal.
This function corresponds to the function of the FB CONVPHA in the 9300 servo inverter.
L _ C O N V P A
± 3 2 7 6 7
d n I n _ p
1
2
b y D i v i s i o n
n O u t
Fig. 2−60 Conversion of phase−angle to analog (L_CONVPA)
VariableName DataType SignalType VariableType Note
dnIn_p Double Integer position VAR_INPUT
nOut Integer analog VAR_OUTPUT The signal is limited to ±32767.
Remainder handling
byDivision Byte VAR CONSTANT RETAIN Division factor
Parameter codes of the instances
VariableName L_CONVPA1 SettingRange Lenze
byDivision C1000 0 ... 31 1
Function
The conversion is made according to the formula:
nOut_a + dnIn_p @
1
2
byDivision
Note!
This FB operates with remainder handling.