Lenze E94P PositionServo with MVOB Manual do Utilizador Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 102
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
30 L S94H201E_13426446_EN
Interface
Test
Step
Action Drive Display
Indication
Safety Status Output
Indication
Failed Test
Indication
5 Deactivate Safety
Input 2. Set Input A3
to Enable
‘F EF’ ‘Activated’ No Trip on display (F_EF) = Safety Input 2 failed to deactivate.
Status Output Deactivated = Safety Input 1 Failed to activate
6 Set Input A3 to disable ‘Dis’ ‘Activated’ Status Output Deactivated = Both Safety Inputs Failed to
activate
7 Deactivate Safety
Input 1. Set Input A3
to Enable
‘F EF’ ‘Deactivated’ No Trip on display (F_EF) = Safety Inputs 1 & 2 failed to
deactivate.
Status Output Activated = Safety Input 1 or Safety Input 2
Failed to deactivate
This procedure will evaluate the following conditions:
a. All Circuits (safety inputs 1 & 2) working Correctly
b. Safety Input 1 failing to activate
c. Safety Input 1 failing to deactivate
d. Safety Input 2 failing to activate
e. Safety Input 2 failing to deactivate
f. Both Safety input 1 and 2 failing to activate
g. Both Safety input 1 and 2 failing to deactivate
Electrical Characteristics
Safety Input1, Safety Input2 and Safety Status are fully isolated from the rest of the drive circuits as shown
in the following diagram.
Safety Inputs Insulated, compatible with single-ended output (+24VDC)
Enable voltage range: 18 to 30VDC
Disable voltage range: 0 to 1.0 VDC
Input Impedance 6.8 k
Safety Status Isolated Open Collector (Grounded Emitter)
Output Load Capability 100mA
Output Max Voltage 30VDC (Collector-Emitter)
Safety Status
Safety Input
2
Safety Input
1
Safety COM
SAFETY COM
SAFETY COM
SAFETY COM
6.8k
6.8k
1
1
1
2
2
2
3
3
3
4
4
4
A
A
A
C
C
C
E
E
E
K
K
K
Vista de página 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 101 102

Comentários a estes Manuais

Sem comentários