RG-MCMOD 26
Drive Control & Communication
NOTE 4 - Acceleration Limits
Acceleration Limits
HP Adjustment Range
.025 - 20 1 - 36000 (0.1 - 3600 sec)
25 - 60 3 - 36000 (0.3 - 3600 sec)
NOTE 5 - Deceleration Limits
Deceleration Limits
HP Adjustment Range
240/200 VAC 480/400 VAC 590/480 VAC without dB with dB
0.25 - 7.5 1 - 7.5 3 - 36000 (0.3 - 3600 sec) 1 - 36000 (0.1 - 3600 sec)
10 - 15 10 - 20 1 - 7.5 5 - 36000 (0.5 - 3600 sec) 1 - 36000 (0.1 - 3600 sec)
20 - 30 25 - 60 10 - 20 10 - 36000 (1.0 - 3600 sec) 2 - 36000 (0.2 - 3600 sec)
25 - 60 20 - 36000 (2.0 - 3600 sec) 2 - 36000 (0.2 - 3600 sec)
NOTE 6 - MAX FREQUENCY (Register 62)
The Maximum limit is 650 Hz on drives with high frequency software.
NOTE 7 - MAX DC BRAKE VOLTAGE (Register 63)
Maximum DC Brake Voltage
Model M3100/M1100 M3200/M1200 M3400/M1400 M3500/M1500
Voltage 240/120 Vac 240/200 Vac 480/400 Vac 590/480 Vac
MAX Brake Voltage 24 V 24 V 48 V 59 V
NOTE 8 - CURRENT (Register 67)
If LINE VOLTS, Register 51, is set to LOW (or set to Auto an the input voltage is low), the range for CURRENT
is 25 - 150%.
NOTE 9 - FX BOOST (Register 70)
FX BOOST Factory Default Settings
HP All Models HP 480/400 Vac
590/480 Vac
240/200Vac
0.25 - 1 5.30% 25 1.80% 1.80%
1.5 - 2 4.40% 30 1.60% 1.60%
3 3.60% 40 1.20% 2.30%
5 3.00% 50 - 60 0.80% 2.10%
7.5 2.70% 75 2.00% N/A
10 2.40% 100 -125 1.90% N/A
15 2.20% 150 1.80% N/A
20 2.00%