S94P01G
10
Technical Data
2.2 Power Ratings
Type
(1)
Output kVA at
Rated Output
Current (8kHz)
(2)
Leakage Current
Power Loss at
Rated Output
Current
(8kHz)
Power Loss at
Rated Output
Current
(16 kHz)
(3)
Units kVA mA Watts Watts
E94_020S1N_X
0.8
Typically >3.5 mA.
Consult factory for
applications requiring
<3.5 mA.
19 21
E94_040S1N_X
1.7
29 30
E94_020S2F_X 0.8 19 21
E94_040S2F_X 1.7 29 30
E94_080S2F_X 3.3 61 63
E94_100S2F_X 4.2 80 85
E94_020Y2N_X 0.8 19 21
E94_040Y2N_X 1.7 29 30
E94_080Y2N_X 3.3 61 63
E94_120Y2~_X 5.0 114 129
E94_180T2~_X 7.5 171 195
E94_020T4N_X 1.7 31 41
E94_040T4N_X 3.3 50 73
E94_050T4N_X 4.2 70 90
E94_060T4~_X 5.0 93 122
E94_090T4~_X 7.5 138 182
2.3 Fuse Recommendations
Type
(1)
AC Line
Input Fuse
(1ø/3ø)
Miniature
Circuit Breaker
(6)
(1ø/3ø)
AC Line Input
Fuse
(4)
or
Breaker
(5)
(N. America)
DC Bus Input
Fuse
(7)
Amp Ratings
E94_020S1N_X M20/M10 C20/C10 20/10 10
E94_040S1N_X M32/M20 C32/C20 30/20 20
E94_020S2F_X M20 C20 20 15
E94_040S2F_X M20 C20 20 20
E94_080S2F_X M32 C32 32 40
E94_100S2F_X M40 C40 40 45
E94_020Y2N_X M20/M16 C20/C16 20/15 15
E94_040Y2N_X M20/M16 C20/C16 20/15 20
E94_080Y2N_X M32/M20 C32/C20 30/20 40
E94_120Y2~_X M50/M32 C50/C32 50/30 55
E94_180T2~_X M40 C40 40 80
E94_020T4N_X M10 C10 10 10
E94_040T4N_X M10 C10 10 20
E94_050T4N_X M16 C16 15 25
E94_060T4~_X M20 C20 20 30
E94_090T4~_X M25 C25 25 40
(1) The first “_” equals “P” for the Model 940 encoder based drive or “R” for the Model 941 resolver based drive.
When the 10th digit is marked by “~”, “N” = No line filter or “F” = Integrated line filter
The second “_” equals “E” for incremental encoder (must have E94P drive) or “R” for the standard resolver (must have E94R drive).
(2)
At 240 VAC line input for drives with suffixes “S1N”, “S2F”, “Y2N”. At 480 VAC line input for drives with suffixes “T4N”.
a. The output power is calculated from the formula: output kVA = [(
3
) x U
LL
x I
rated
] / 1000
b. The actual output power (kW) depends on the motor in use due to variations in motor rated voltage, rated speed and power factor, as well as
actual max operating speed and desired overload capacity.
c. Typical max continuous power (kW) for PM servo motors runs 50-70% of the kVA ratings listed.
(3) At 16 kHz, de-rate continuous current by 17%
(4) Installations with high fault current due to large supply mains may require a type D circuit breaker.
(5) UL Class CC or T fast-acting current-limiting type fuses, 200,000 AIC, preferred. Bussman KTK-R, JJN, JJS or equivalent.
(6) Thermal-magnetic type breakers preferred.
(7) DC-rated fuses, rated for the applied voltage. Examples Bussman KTM or JJN as appropriate.