Lenze Function library LenzeIO1000Drv Manual do Utilizador Página 15

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 64
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 14
DMS 1.0 EN - 07/2011 - TD05 L 15
Function library "LenzeIo1000Drv"
Function blocks
L_io1000ParAiTemperature - Parameterise temperature measurement
Inputs
Identifier/data type Information/possible settings
bExecute
BOOL
FALSEÊTRUE Start parameter setting of the analog input module
dwHandle
DWORD
9400 ServoPLC: Handle created by FB L_CanInit
Drive PLC, 9300 Servo PLC, ECS: 10
byNodeAdr
BYTE
1 ... 127 CAN node address of the I/O system
byAnalogModuleNo
BYTE
1 ... 64 Number of the analog input module
byNoOfChannels
BYTE
Number of channels of the I/O system
2 EPM-S405
4 EPM-S404
bDiagnosticAlarm
BOOL
TRUE Enable diagnostic alarm
byTemperatureSystem
BYTE
Temperature system
C
F
2K
byFilter
BYTE
Activate interference frequency suppression
160Hz
250Hz
bWireBreakDetection
_CH1 ... _CH4
BOOL
TRUE Activate open circuit detection channel 1 ... 4
byFunction_CH1 ... _CH4
BYTE
Function channel 1 ... 4
see system manual "I/O system 1000":
EPM-S404: Chapter 7.9.1
EPM-S405: Chapter 7.9.2
bySampling_CH1 ... _CH4
BYTE
Conversion time channel 1 ... 4
see system manual "I/O system 1000":
EPM-S404: Chapter 7.9.1
EPM-S405: Chapter 7.9.2
bLimitAlarm_CH1 ... _CH4
BOOL
TRUE Activate limit value monitoring channel 1 ... 4
nUpperLimit_CH1 ... _CH4
BYTE
Upper limit value channel 1 ... 4
nLowerLimit_CH1 ... _CH4
BYTE
Lower limit value channel 1 ... 4
Vista de página 14