Architecture: The ApplicationTemplate in detail
Internal Control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[9-30] Instance of the "Module1" machine module in the variable view
If "Internal Control" is active, ...
...a write operation by the master has no effect on the module. The write operation of the
module's intrinsic application (MAP) will prevail instead.
...a read operation by the master or the module's intrinsic MAP supplies the current machine
module values.
If "Internal Control" is deactivated, ...
...a write operation by the master to the module can be executed.
...a write operation of the module's intrinsic MAP will prevail.
...a read operation by the master or the module's intrinsic MAP supplies the current machine
module values.
The following is highlighted:
•The switches (TRUE/FALSE) for
activating the "Internal Control"
(xInternalControl)
The references to the module's
intrinsic baseChannel (blue marking)
Vista de página 102