Vista de página 85
Electrical installation
Power terminals
Mains connection
4
86
EDKCSEE040 DE/EN/FR 4.0
Fuses
Use the following circuit-breakers or UL-approved fuses to protect the mains
cable(seeFig.4-2( 85)):
Power supply
module
Dimensioning according to IEC/EN Dimensioning to UL
Circuit-breaker Cable
cross-section
[mm
2
]
UL fuse AWG
ECSxE012 C16 A 2.5 25A 12
ECSxE020 C16 A 2.5 25A 12
ECSxE040
: C40A 10
1)
35 A 8
1)
/: , C32A 6 35 A 10
: C40A 6
2)
35 A 10
2)
: C40A 10 35 A 8
1) Cable without wire end ferrule or with pin-end connector
2) Cable length max. 30 cm
Warnings!
ƒ Use UL-approved cables, fuses and fuse holders only.
ƒ UL fuse:
Voltage 500 ... 600 V
Tripping characteristic ”H”, ”K5” or ”CC”
Replacing defective fuses
Danger!
Hazardous electrical voltage
Components can carry hazardous voltages up to 3 minutes after
power-off.
Possible consequences:
ƒ Death or s evere injuries when touching the device.
Protective measures:
ƒ Replace fuses in the deenergised state only.
Set controller inhibit (CINH) for all axis modules in DC-bus
operation and disconnect all power supply modules from the
mains.