Technical d ata
3-2
L
BA2141 EN 1.0
3.3 Rated data
Field Values
Voltage supply 24 V DC ñ 10 %; max. 120 mA
Communication profile LONMARK
®
Functional Profile “Variable Speed Motor Drive”
Communication medium FTT - 10 A (Free Topology Transceiver)
Insulation voltage between bus and ... Rated insulation voltage Insulation type
Earth reference / PE 50 V AC Mains isolation
External supply (terminal 39/59) 50 V AC Mains isolation
Power stage
820X / 821X 270 V AC Basic insulation
822X / 8200 vector 270 V AC Double insulation
93XX 270 V AC Double insulation
Control terminals
820X / 8200 vector (with internal supply) 0VAC No mains isolation
8200 vector (with external supply 100 V AC Basic insulation
821X 50 V AC Mains isolation
822X 270 V AC Basic insulation
93XX 270 V AC Basic insulation
Degree of pollution VDE0110, part 2, pollution degree 2
3.4 Dimensions
Service
LON
L
24V DC FTT
2141
62
75
18
23
Fig. 3-1 Dimensions of the 2141 fieldbus module (all dimensions in mm)