Parameter setting
6-39
L
BA2141 EN 1.0
6.5.3.2 Control word for 8200 vector
Bit
8200vector
Default setting:
C0001=3 if C0007 < 52
Default setting:
C0001=3 if C0007 > 51
00,
00 = C0046 active
01 = NSET1-JOG1 (C0037) active
01
10 = NSET1-JOG2 (C0038) active
11 = NSET1-JOG3 (C0039) active
Freely configurable by user
02 DCTRL1-CW/CCW
0=notactive
1=active
03 AIF-CTRL-QSP
0=notactive
1=active
04 NSET1-RFG1-STOP
0=notactive
1=active
05 NSET1-RFG1-0
0=notactive
1=active
06 MPOT1-UP
0=notactive
1=active
Freely configurable by user
07 MPOT1-DOWN
0=notactive
1=active
08 Freely configurable by user
09 AIF-CTRL-CINH
0=notactive
1=active
10 AIF-CTRL-TRIP-SET
0=notactive
1=active
11 AIF-CTRL-TRIP-RESET
0 -> 1 = Edge from 0 to 1
12 DCTRL1-PAR2/4
0=notactive
1=active
13 DCTRL1-PAR3/4
0=notactive
1=active
Freely configurable by user
14 MCTRL1-DCB
0=notactive
1=active
15 Freely configurable by user