Drive PLC Developer Studio
Working with projects and objects
6-23
l
DDS EN 2.3
QSP Trip/CINH Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint • Fail QSP is activated
• Code C168, subcode 1
Error entry: none
• CINH is activated
• Code C168, subcode 1
Error entry: none
• Motor continues running
• Code C168, subcode 1
Error entry: none
Task overflo w • Fail QSP is activated
• Code C168, subcode 1
Error entry: Task overflow
• CINH is activated
• Code C168, subcode 1
Error entry: Task overflow
• Motor continues running
• Code C168, subcode 1
Error entry: none
Drive PLC
Automation system without drive function
Note!
The configuration of the digital outputs
– remains unchanged with the extension modules.
– remains unchanged with the Drive PLC.
QSP Trip/CINH Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint • CINH is activated
• Code C168, subcode 1
Error entry: none
• Motor continues running
• Code C168, subcode 1
Error entry: none
Task overflo w • CINH is activated
• Code C168, subcode 1
Error entry: Task overflow
• Motor continues running
• Code C168, subcode 1
Error entry: none