E84AYCEC communication manual (Ethernet POWERLINK)
Process data transfer
Access to process data / PDO mapping
46 L EDS84AYCEC EN 3.0 - 09/2012
7.1 Access to process data / PDO mapping
Process data (MCI-PDOs) are transferred via the MCI interface.
A maximum of 16 words are exchanged per direction.
The process data are accessed via the port blocks LP_MciIn and LP_MciOut. These port
blocks are also referred to as process data channels.
The port block LP_MciIn maps the received MCI-PDOs.
The port block LP_MciOut maps the MCI-PDOs to be sent.
The port/function block interconnection for the process data objects (PDO) is carried
out with the Lenze »Engineer«.
[7-1] Outer and inner data transfer between bus system, controller and application
/3B0FL,Q
"
E&WUOB%
E&WUOB%
Z&WUO
E,QB%
E,QB%
Z,Q
Z,Q
GQ,QBS
/3B0FL2XW
E6WDWHB%
E6WDWHB%
Z6WDWH
E2XWB%
E2XWB%
Z2XW
Z2XW
GQ2XWBS
"
)LHOGEXV

$SSOLFDWLRQ
)%LQWHUFRQQHFWLRQ
&RPPXQLFDWLRQPRGXOH
0&,LQWHUIDFH
Software manual / »Engineer« online help for the Inverter Drive 8400
Here you can find detailed information on the port/function block
interconnection in the »Engineer« and on the port blocks.