E84AYCEC communication manual (Ethernet POWERLINK)
Parameter reference
Parameters of the communication module
70 L EDS84AYCEC EN 3.0 - 09/2012
C13040
The describing bit field has the following structure:
Parameter | Name:
C13040 | 0x1F82 Feature Flags
Data type: UNSIGNED_32
Index: 11535
d
= 2D0F
h
The code displays the Ethernet POWERLINK features implemented by the EPL node.
Lenze standard value: 0x00000207
Value is bit-coded:
Bit 0 ... 31 see below
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Bit Value Description
0 (LSB) 0 Asynchronous access
1 Isochronous access
1 0 No SDO by UDP/IP
1 SDO by UDP/IP
2 0 No SDO by EPL "ASnd"
1 SDO by EPL "ASnd"
3 0 No SDO integrated in PDO
1 SDO integrated in PDO
4 0 No "NMT Info Services"
1 "NMT Info Services" supported
5 0 No extended "NMT State Commands"
1 Extended "NMT State Commands" supported
6 0 No dynamic PDO mapping
1 Dynamic PDO mapping supported
7- Reserved / No function
8 0 No configuration manager function
1 Configuration manager function
9 0 Only isochronous cyclic access permitted.
1 Isochronous multiplexed access possible.
10 0 No address assignment via software
1 Address assignment via software
11 - Reserved / No function
12 0 No "Ethernet POWERLINK to standard Ethernet" router function.
1 The device can be used as an "Ethernet POWERLINK to standard Ethernet" router (router
type 1).
13 0 No "Ethernet POWERLINK to fieldbus" router function.
1 The device can be used as an "Ethernet POWERLINK to fieldbus" router (router type 1).
14 ... 31
(MSB)
- Reserved / No function