Electrical installation
Power terminals
Connection plan for mimimum wiring with external brake resistor
4
97
EDKCSDE040 DE/EN/FR 4.0
Wiring of external brake resistor ERBM...
T1
T2
BR1
+UG
X22
X6
ERBM...
ECSCE...
R
B_ext
< 0.5 m
BR0
+UG
-UG
PE
PE
T1
T2
BR1
+UG
X22
X6
ERBM...
ECSCE...
R
B_ext
BR0
+UG
-UG
PE
<10cm
PE
<5m
"
"
ECSXE011
Fig. 4−5 Connection of external brake resistors, ERBM series
HF−shield termination by large surface PE connection
Twisted cables
Wiring of external brake resistor of ERBS.../ERBD... series
T1
T2
BR1
+UG
X22
X6
ECSxE...
BR0
+UG -UG
PE
<5m
ERBS... / ERBD...
R
B
RB1 RB2 T1 T2
PE
"
"
T1
T2
BR1
+UG
X22
X6
ECSxE...
BR0
+UG -UG
PE
ERBS... / ERBD...
R
B
RB1 RB2 T1 T2
PE
< 0.5 m
ECSXE010
Fig. 4−6 Wiring of external brake resistor, ERBS.../ERBD... series
HF−shield termination by large surface PE connection
Twisted cables