9400 HighLine | Parameter setting & configuration
Commissioning
Controller replacement
32 Firmware 1.37 - 09/2006 L
3.5 Controller replacement
Scenario: The controller has failed in a running system.
Note!
For the following procedure described we assume that the memory module and
possibly available extension modules in the controller and the motor are not
affected by the failure.
Worksteps
Replacement of the controller:
1. Replace controller.
See Mounting Instructions for the controller!
2. Insert the memory module of the failed controller into the replacement device.
3. If further extension modules are plugged into the failed controller, these must be inserted into the
replacement device as well.
Further steps are not required since all data needed are on the memory module.