Vista de página 151
PLC Designer V2.x| Lenze Application Samples
Working with the sample projects
8200 vector - "LAS_40_INTF_Can_82_Speed" sample project
152 L 1.3 EN - 07/2012
8.6.4 Program structure in the »PLC Designer«
How to proceed:
1. In the »PLC Designer«, open the "LAS_40_INTF_Can_82_Speed.pro" sample
project.
2. Load the project to the IPC and Go online.
8.6.4.1 Control configuration
The CAN master (ID = 0) is the control section of the system configuration
Below the CAN master the 8200 vector (CAN node ID = 5) is attached.
The 8200 vector is embedded in the form of a device-independent EDS file
(LenzeDrive_Can1_4Word).
One PDO for CAN-Input and one PDO for CAN-Output is used, respectively.
The transmission mode is sync-controlled (10 ms).