Lenze PLC Designer V2.x Manual do Utilizador Página 300

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 336
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 299
PLC Designer V2.x| Lenze Application Samples
The L_SCB_CANBasic.lib library
L_SCB_SDO_TransferTable - transfer parameter list
300 L 1.3 EN - 07/2012
Outputs
byNodeNumber
BYTE
Node number
byMasterNumber
BYTE
Interface number (0...3)
xUseFixAdressing
BOOL
TRUE: Fixed addressing activated
dwAdrParameterData
DWORD
Address of the SCB structure
dwSizeParameterData
DWORD
Size of the SCB structure
xUseCodeAsIndex
BOOL
TRUE: Indices to CAN-Open
Identifier/data type Information/possible settings
xDone
BOOL
TRUE: Process completed
xBusy
BOOL
TRUE: Write or read process active
xError
BOOL
"Error" status signal
FALSE No error detected
TRUE Error when reading the data
wErrId
WORD
Error number
byIndex
BYTE
Byte index (0...7)
Identifier/data type Information/possible settings