2Introduction
2.4 Parameter setting and configuration
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Service status
If you request the "Send safe data to device" function in the Safe Transfer dialog box via the Send
button, the drive-based safety system changes to the "Service status" which is required for a safe
parameter setting.
Send safe data ( 45)
The service status means:
The standard stop is active and the drive is safely switched to torqueless operation (STO).
With safety option 30, the safe inputs are evaluated as OFF state.
The communication via safety bus is - if possible - active, but passivated.
Supported interfaces for a safe parameter setting
A safe parameter setting with the »Engineer« is supported via the following interfaces:
Diagnostic interface X70
CANopen system bus interface
Note!
The service status is also active if the parameter set in the memory module does not
correspond to the parameter set in the drive-based safety system during the
initialisation.
The service status can be exited by reinitialising the drive-based safety system, i.e. the
communication via the safety bus is interrupted.