3 Safe configuration
3.3 Plausibility check
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.3 Plausibility check
Before transmitting the parameter set to the drive-based safety system, a plausibility check always
takes place.
With the Plausibility check... command in the Context menu (right mouse button) of the parameter
list you can start the plausibility check manually, to check the changes made in the parameter
settings with regard to plausibility.
• After the plausibility check a status message indicates whether the plausibility check was
successful.
• If the plausibility check failed, the status message contains the parameters with implausible
settings.
Tip!
C15016
displays the parameter set version of the drive-based safety system.
3.4 General parameters
Short overview of "General" parameter group:
Module ID
Unique identification (1 ... 65534) for the safe device.
Safety address
The safety address serves as a unique identification of the drive-based safety system in systems
with several drives.
Setting of the safety address
( 26)
Note!
Only a plausible parameter set can be transmitted to the drive-based safety system
using the "Send safe data" function!
Parameter Information Lenze setting
-Module ID 1
C15111
Safety address 0