6 Commissioning
6.5 Drive synchronisation
41
Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.5 Drive synchronisation
Examples of the use of drive synchronisation via POWERLINK:
Implementation of the "electrical shaft"
Specification of cyclic position information
Exactly simultaneous data processing of several drives
Optimisation of the processing times of cyclic process data (PDO).
Settings in the »Engineer«
Set the MXI slot of the communication module as synchronisation source in code C01120 of the
Servo Drive 9400.
The sync cycle time C01121 and the sync phase position C01122 are automatically calculated
from the communication module. Default settings of these parameters are ignored.
It is not necessary to adjust the sync tolerance C01123 and the sync increment C01124.
Reference manual/»Engineer« online help for Servo Drive 9400
Here you can find detailed information on drive synchronisation and the corresponding