Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17 112
12 Visualisation with »VisiWinNET®«
12.6 OPC tunnel for local visualisation (integrated control system)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.6 OPC tunnel for local visualisation (integrated control system)
[12-2] Local visualisation on a controller
Note!
There is no OPC server available for PROFIBUS and PROFINET.
Controller c300/p300:
The OPC communication for »VisiWinNET« is exclusively available for Controller p300
without
PLC.
Otherwise, only the Lenze "Logic&Motion" direct driver can be used for the data
exchange between »VisiWinNET« and PLC.
The local »VisiWinNET®« Runtime on the
controller uses the local OPC tunnel to
access the respective OPC server
(DataManager, CAN/EtherCAT, SoftPLC).
For a local visualisation, the OPCServer.ini
configuration file must be adapted. The
configuration file is on the memory card of
the controller, directory: \USBStorage.
Configure OPC tunnel
( 119)