13 Parameter reference
13.3 Voltage buffering by external UPS (optional, for Controller 3241 C)
159
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C0207
C0208
C0209
C0210
C0211
Parameter | Name:
C0207 | UPS: Battery / capacitor voltage
Data type: FLOAT_32
Index: 24368
d
= 5F30
h
Voltage of the battery/capacitor in [V]
Display range (min. value | unit | max. value)
V
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0208 | UPS: Display lighting after voltage failure
Data type: UNSIGNED_8
Index: 24367
d
= 5F2F
h
Behaviour of the display lighting after a voltage failure.
Selection list (Lenze setting printed in bold) Info
0Off Activate display lighting
1 On Deactivate display lighting
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0209 | UPS: Number of voltage dips
Data type: UNSIGNED_8
Index: 24366
d
= 5F2E
h
Indicates the number of voltage failures.
Display range (min. value | unit | max. value)
0 255
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0210 | UPS: Supply voltage OK
Data type: UNSIGNED_8
Index: 24365
d
= 5F2D
h
Status of the supply voltage
Selection list (read only) Info
0 No
1 Yes
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0211 | UPS: Voltage failure
Data type: UNSIGNED_8
Index: 24364
d
= 5F2C
h
Status of voltage failure (present/not present)
Selection list (read only)
0 No
1 Yes
Read access Write access CINH PLC-STOP No transfer