Lenze c300 Manual do Utilizador Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 195
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 34
5 Commissioning the controller
5.4 Configuring the controller
35
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.4.2.2 Cabinet Controller without external monitor panel (c300/3221 C)
To configure a Cabinet Controller without a connected monitor panel (e.g. Controller 3221 C), a PC/
laptop with the suitable addresses (IP address, subnet mask, default gateway) is required.
Connect the PC/laptop to the controller by means of a "crossed" network cable.
Change the settings on an HTML compliant browser:
Setting IP addresses on the Engineering PC (example: Windows® XP)
( 46)
Connection establishment: enter the IP address of the controller in the browser: 192.168.5.99
(Lenze default setting).
In »WebConfig«, click the Ethernet button.
Enter the desired IP address, subnet mask and default gangway of the Controller.
•Click Accept & Save all.
•Set Use IP configuration to the value "Activate device".
Click again Accept & Save all in order to save the network settings permanently.
Vista de página 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 194 195

Comentários a estes Manuais

Sem comentários