Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17 120
12 Visualisation with »VisiWinNET®«
12.7 OPC tunnel for external visualisation (remote access)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.7 OPC tunnel for external visualisation (remote access)
12.7.1 Windows® CE operating system
[12-3] Remote access with one visualisation controller ("Visu") and one controller
The »VisiWinNET®« Runtime of the external
controller, Controller(Visu), accesses the OPC
servers of the control system Controller via the
OPC tunnels (1, 2).
Note!
There is no OPC server available for PROFIBUS and PROFINET.
Controller c300/p300:
• The OPC communication for »VisiWinNET« is exclusively available for Controller p300
without
PLC.
• Otherwise, only the Lenze "Logic&Motion" direct driver can be used for the data
exchange between »VisiWinNET« and PLC.