Lenze PLC Designer PLC Designer (R2-x) Manual do Utilizador Página 745

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 844
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 744
L-force | PLC Designer
PLC Designer Visualization
DMS 3.2 EN 02/2011 TD29 743
Additional settings:
Frame inside, Frame outside: If one or both of these options is/are activated, an inner
or outer frame will be added to the scale arc.
Additional arrow: In addition to the main pointer a little arrow will indicate the
current value directly on the scale.
No Scaling: If this option is activated, the inserted element cannot get resized.
20.6.23 Bar Display
Dialog for the configuration of a Bar Display element
This dialog will be opened as soon as you insert a Bar Display element into a
visualization object. A Preview is part of the dialog, immediately showing how the
element will look as a result of the currently set parameters:
Diagram type: Choose one of the options: 'Scale beside bar', 'Scale inside bar' and 'Bar
inside scale'.
Orientation: Define one of the options: Horizontal or Vertical bar.
Running direction: Choose whether the bar should be elongated corresponding to a
growing value of the assigned variable in Left – Right or in Right – Left direction.
Bar color: This button opens the standard dialog for choosing a color. Define a color
for the bar in normal state (no alarm). If option 'Use color areas' (see below) is
activated, no entries are possible.
Vista de página 744
1 2 ... 740 741 742 743 744 745 746 747 748 749 750 ... 843 844

Comentários a estes Manuais