7.6.7.7 Ramps
The DRIVECOM profile 21 provides two ramps for the speed setpoint:
l The absolute ramp is determined by the following ramp gradient:
dê~ÇáÉåí =
aÉäí~|ëéÉÉÇ
aÉäí~|íáãÉ
The absolute ramps in the DRIVECOM profile 21 are ”acceleration”,
”deceleration” and ”quick stop”.
l The relative ramp is determined by the following ramp gradient:
dê~ÇáÉåí =
péÉÉÇ êÉÑÉêÉåÅÉ î~äìÉ
aÉäí~|íáãÉ
This definition corresponds to the Lenze ramp functions L-C0012 and L-C0013.
The relative ramps in the DRIVECOM profile 21 are ”acceleration time”,
”deceleration time” and ”quick-stop time”.
The ”ramp-min function” determines and activates the slower ramp. The absolute
ramps are deactivated in Lenze setting.
This parameter contains data of the absolute speed ramp for acceleration.
Ramp gradient:
Gradient =
Delta_speed
Delta_time
The parameter is mapped to the Lenze acceleration ramp (L-C0012) via the
”ramp-min-function”.
”Delta_time“ = 0: Ramp is switched off.
Parameter name (Index) Subindex Data structure Data typ e Value range
Speed acceleration (6048
hex
)
1 RS (21
hex
) U32 0 to 4294967295
0: Delta_speed [rev/min]
2 RS (21
hex
) U16 0 to 65535
0 (ramp is switched off):
Delta_time [sec]
The ”ramp-min function” determines and activates the slower ramp. The absolute
ramps are deactivated in Lenze setting.
Speed ramps fro acceleration