3.6 Code table
9300 Servo PLC
Appendix
3−128
L
9300 Servo PLC EN 5.1
Code InformationPossible settingsLCDCode Information
SelectionLenze
LCD
C0108 FCODE (gain) Freely configurable code (relative analog signals)
−199.99 {0.01 %} 199.99
1 100.00 FCODE_nC108_1_a
2 100.00 FCODE_nC108_2_a
C0109 FCODE (offset) Freely configurable code (relative analog signals)
−199.99 {0.01 %} 199.99
1 0.00 FCODE_nC109_1_a
2 0.00 FCODE_nC109_2_a
C0111 Rr tune 100 % Adjustment of the rotor resistance
(Particularly recommended for non−Lenze motors and high
field weakening.)
Adjustment in % of the rated rotor resistance of the
motor.
50.00 {0.01 %} 199.99
C0114 DIGIN pol Terminal polarity
0 HIGH active
1 LOW active
1 1 X5/E1
2 1 X5/E2
3 0 X5/E3
4 0 X5/E4
5 0 X5/E5
C0118 DIGOUT pol Terminal polarity
0 HIGH active
1 LOW active
1 0 X5/A1
2 0 X5/A2
3 0 X5/A3
4 0 X5/A4
C0120 OC6 limit 0 Threshold for the I
2
× t−monitoring (motor).
0 = I
2
× t−monitoring is switched off
I
2
× t > C0120 Trip OC6
0 {1 %} 120
C0121 OH7 limit 150 Temperature threshold for motor temperature prewarning
"TMot > C0121" (fault OH7)
45 {1 °C} 150
C0122 OH4 limit 85 Temperature threshold for heatsink temperature
prewarning "Tht > C0122" (fault OH4)
45 {1 °C} 85
C0125 Baud rate 0 LECOM baud rate for accessory module 2102
0 9600 bps
1 4800 bps
2 2400 bps
3 1200 bps
4 19200 bit/s
C0126 MONIT CE0 3 Configuration for communication error "CE0" with
automation interface
0 TRIP
2 Warning
3 Off
C0127 OC8 limit 0 Threshold for the I
2
× t−advance warning (motor).
0 = I
2
× t−warning is switched off
I
2
× t > C0127 fault message OC8 (response set
in C606)
0 {1 %} 120
Comentários a estes Manuais