Lenze DDS Target 9300 Servo PLC V8.x Manual do Utilizador Página 158

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 169
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 157
9300 Servo PLC
Appendix
3−152
L
9300 Servo PLC EN 5.1
Auto−increment access
The four data bytes are always read/written through "auto−increment access", i.e. the pointer to the
address in the selected RAM block is automatically incremented by four bytes after reading code
C0507 or writing code C0508:
0
Offset
C0505
auto-increment
(+4 bytes)
65532
4 bytes
4 bytes
4 bytes
4 bytes
RAM
block
4 bytes
0
Offset
C0505
auto-increment
(+4 bytes)
65532
4 bytes
4 bytes
4 bytes
4 bytes
4 bytes
0
Offset
C0505
auto-increment
(+4 bytes)
65532
4 bytes
4 bytes
4 bytes
4 bytes
4 bytes
1. 2. 3.
C0507 C0507
C0507
Fig. 3−2 Example: Reading successive double integer values from the RAM block through auto−increment access
Vista de página 157
1 2 ... 153 154 155 156 157 158 159 160 161 162 163 ... 168 169

Comentários a estes Manuais

Sem comentários