2.1 AIF1_IO_AutomationInterface (node number 41)
9300 Servo PLC
System blocks
2−14
L
9300 Servo PLC EN 5.1
System variables
Variable Data type Signal type Address Display
code
Display
format
Note
AIF1_wDctrlStat Word %QW41.0
AIF1_nOutW1_a
Integer Analog
%QW41.1 C0858/1
dec [%]
AIF1_nOutW2_a %QW41.2 C0858/2
AIF1_nOutW3_a %QW41.3 C0858/3
AIF1_bFDO0_b
Bool Binary
%QX41.2.0
C0151/4 hex
Display code in hex
as double word
.. ...
AIF1_bFDO15_b %QX41.2.15
AIF1_bFDO16_b %QX41.3.0
.. ...
AIF1_bFDO31_b %QX41.3.15
AIF1_dnOutD1_p Double integer Position %QD41.1 C0859 dec [inc]
User data
The 8 bytes of user data to be sent can be written to via several variables of different data types
simultaneously. Thus the data can be transferred by the PLC program as
binary information (1 bit)
status word/quasi−analog value (16 bits)
phase information (32 bits)
according to the requirements.
Byte Variable (1 bit) Variable (16 bits) Variable (32 bits)
1, 2
AIF1_wDctrlStat
Notes:
Drive PLC:
All variables assigned to byte 1/2 can be written to by the PLC program.
9300 Servo PLC:
Bytes 1 and 2 can be used to transfer the status word from the SB DCTRL_DriveControl.
To do this, connect the variable DCTRL_wStat of the SB DCTRL_DriveControl with the variable AIF1_wDctrlStat.
In addition to signals such as IMP and CINH, the SB DCTRL_DriveControl status word contains some freely
assignable signals which can be written to via the variables DCTRL_bStateB.._b of the SB DCTRL_DriveControl.
3, 4
AIF1_nOutW1_a
5, 6 AIF1_bFDO0_b
...
AIF1_bFDO15_b
AIF1_nOutW2_a
AIF1_dnOutD1_p
7, 8 AIF1_bFDO16_b
...
AIF1_bFDO31_b
AIF1_nOutW3_a
Tip!
Avoid simultaneous overwriting via different variable types to ensure data consistency.
Thus bytes 5 and 6 should only be written to
by the variable AIF1_dnOutD1_p,
by the variable AIF1_nOutW2_a or
by the variables AIF1_bFDO0_b ... AIF1_bFDO15_b.